VMWare ESXi-update CLI:

Download des entsprechenden Packs von https://www.vmware.com/patchmgr/findPatch.portal

--> Upload in lokalen Datastore z.B.: /vmfs/volumes/datastore/install

Anschließend ESX-Server in Maintenance Mode versetzen - entweder über Native Client oder über CLI

vim-cmd hostsvc/maintenance_mode_enter

im Anschluss in das Installverzeichnis wechseln:

cd /vmfs/volumes/Datastore/Install

Update durchführen:

esxcli software vib install -d "/vmfs/volumes/Datastore/Install/update-from-esxi5.0-5.0_update03.zip"

Ausgabe:
Installation Result
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true
   VIBs Installed: VMware_bootbank_esx-base_5.0.0-3.41.1311175, VMware_bootbank_esx-tboot_5.0.0-2.26.914586, VMware_bootbank_ipmi-ipmi-si-drv_39.1-4vmw.500.2.26.914586, VMware_bootbank_misc-drivers_5.0.0-3.41.1311175, VMware_bootbank_net-bnx2x_1.61.15.v50.1-2vmw.500.2.38.1311177, VMware_bootbank_net-e1000_8.0.3.1-2vmw.500.2.35.1254542, VMware_bootbank_net-e1000e_1.1.2-3vmw.500.2.26.914586, VMware_bootbank_net-igb_2.1.11.1-3vmw.500.2.26.914586, VMware_bootbank_net-ixgbe_2.0.84.8.2-11vmw.500.2.26.914586, VMware_bootbank_net-tg3_3.123b.v50.1-1vmw.500.2.26.914586, VMware_bootbank_scsi-hpsa_5.0.0-17vmw.500.3.41.1311175, VMware_bootbank_scsi-lpfc820_8.2.2.1-18vmw.500.2.26.914586, VMware_bootbank_scsi-mptsas_4.23.01.00-5vmw.500.1.18.768111, VMware_locker_tools-light_5.0.0-3.41.1311175
   VIBs Removed: VMware_bootbank_esx-base_5.0.0-1.11.623860, VMware_bootbank_esx-tboot_5.0.0-0.0.469512, VMware_bootbank_ipmi-ipmi-si-drv_39.1-4vmw.500.0.0.469512, VMware_bootbank_misc-drivers_5.0.0-1.11.623860, VMware_bootbank_net-bnx2x_1.61.15.v50.1-1vmw.500.0.0.469512, VMware_bootbank_net-e1000_8.0.3.1-2vmw.500.0.7.515841, VMware_bootbank_net-e1000e_1.1.2-3vmw.500.1.11.623860, VMware_bootbank_net-igb_2.1.11.1-3vmw.500.0.0.469512, VMware_bootbank_net-ixgbe_2.0.84.8.2-10vmw.500.0.0.469512, VMware_bootbank_net-tg3_3.110h.v50.4-4vmw.500.0.0.469512, VMware_bootbank_scsi-hpsa_5.0.0-17vmw.500.0.0.469512, VMware_bootbank_scsi-lpfc820_8.2.2.1-18vmw.500.0.0.469512, VMware_bootbank_scsi-mptsas_4.23.01.00-5vmw.500.0.0.469512, VMware_locker_tools-light_5.0.0-1.11.623860
   VIBs Skipped: VMware_bootbank_ata-pata-amd_0.3.10-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-atiixp_0.4.6-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-cmd64x_0.2.5-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-pdc2027x_1.0-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-serverworks_0.4.3-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-sil680_0.4.8-3vmw.500.0.0.469512, VMware_bootbank_ata-pata-via_0.3.3-2vmw.500.0.0.469512, VMware_bootbank_block-cciss_3.6.14-10vmw.500.0.0.469512, VMware_bootbank_ehci-ehci-hcd_1.0-3vmw.500.1.11.623860, VMware_bootbank_ima-qla4xxx_2.01.07-1vmw.500.0.0.469512, VMware_bootbank_ipmi-ipmi-devintf_39.1-4vmw.500.0.0.469512, VMware_bootbank_ipmi-ipmi-msghandler_39.1-4vmw.500.0.0.469512, VMware_bootbank_misc-cnic-register_1.1-1vmw.500.0.0.469512, VMware_bootbank_net-be2net_4.0.88.0-1vmw.500.0.7.515841, VMware_bootbank_net-bnx2_2.0.15g.v50.11-5vmw.500.0.0.469512, VMware_bootbank_net-cnic_1.10.2j.v50.7-2vmw.500.0.0.469512, VMware_bootbank_net-enic_1.4.2.15a-1vmw.500.0.0.469512, VMware_bootbank_net-forcedeth_0.61-2vmw.500.0.0.469512, VMware_bootbank_net-nx-nic_4.0.557-3vmw.500.1.11.623860, VMware_bootbank_net-r8168_8.013.00-3vmw.500.0.0.469512, VMware_bootbank_net-r8169_6.011.00-2vmw.500.0.0.469512, VMware_bootbank_net-s2io_2.1.4.13427-3vmw.500.0.0.469512, VMware_bootbank_net-sky2_1.20-2vmw.500.0.0.469512, VMware_bootbank_ohci-usb-ohci_1.0-3vmw.500.0.0.469512, VMware_bootbank_sata-ahci_3.0-6vmw.500.1.11.623860, VMware_bootbank_sata-ata-piix_2.12-4vmw.500.1.11.623860, VMware_bootbank_sata-sata-nv_3.5-3vmw.500.0.0.469512, VMware_bootbank_sata-sata-promise_2.12-3vmw.500.0.0.469512, VMware_bootbank_sata-sata-sil_2.3-3vmw.500.0.0.469512, VMware_bootbank_sata-sata-svw_2.3-3vmw.500.0.0.469512, VMware_bootbank_scsi-aacraid_1.1.5.1-9vmw.500.1.11.623860, VMware_bootbank_scsi-adp94xx_1.0.8.12-6vmw.500.0.0.469512, VMware_bootbank_scsi-aic79xx_3.1-5vmw.500.0.0.469512, VMware_bootbank_scsi-bnx2i_1.9.1d.v50.1-3vmw.500.0.0.469512, VMware_bootbank_scsi-fnic_1.5.0.3-1vmw.500.0.0.469512, VMware_bootbank_scsi-ips_7.12.05-4vmw.500.0.0.469512, VMware_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.500.0.0.469512, VMware_bootbank_scsi-megaraid-sas_5.34-1vmw.500.1.11.623860, VMware_bootbank_scsi-megaraid2_2.00.4-9vmw.500.0.0.469512, VMware_bootbank_scsi-mpt2sas_06.00.00.00-6vmw.500.1.11.623860, VMware_bootbank_scsi-mptspi_4.23.01.00-5vmw.500.0.0.469512, VMware_bootbank_scsi-qla2xxx_901.k1.1-14vmw.500.0.0.469512, VMware_bootbank_scsi-qla4xxx_5.01.03.2-3vmw.500.0.0.469512, VMware_bootbank_scsi-rste_2.0.2.0088-1vmw.500.1.11.623860, VMware_bootbank_uhci-usb-uhci_1.0-3vmw.500.0.0.469512

--> Reboot durchführen
--> gegebenenfalls vSphere Client updaten
--> gegebenenfalls VMWare Tools auf VM's updaten

 

Gleiche Methode anwenden bei Patches:

Bsp:
esxcli software vib install -d "/vmfs/volumes/Datastore/Install/ESXi550-201809001.zip"

Es kann vorkommen, dass aus historischen Zeiten (ver. 5.0) Custom-Images auf den entsprechenden Server das Update erst einmal verweigern, da noch veraltete Treiber in Form von VIB's vorhanden sind (was bei mir vorkam bei Dell / Fujitsu Custom. Images):

Fehlermeldung:

VIB Brocade_bootbank_scsi-bfa_3.1.0.0-1OEM.500.0.0.472560 requires vmkapi_2_0_0_0, but the requirement cannot be satisfied within the ImageProfile.
VIB Brocade_bootbank_net-bna_3.1.0.0-1OEM.500.0.0.472560 requires com.vmware.driverAPI-9.2.0.0, but the requirement cannot be satisfied within the ImageProfile.
VIB Brocade_bootbank_net-bna_3.1.0.0-1OEM.500.0.0.472560 requires vmkapi_2_0_0_0, but the requirement cannot be satisfied within the ImageProfile.
VIB Brocade_bootbank_scsi-bfa_3.1.0.0-1OEM.500.0.0.472560 requires com.vmware.driverAPI-9.2.0.0, but the requirement cannot be satisfied within the ImageProfile.

hier die entsprechend nicht mehr benötigten Softwarepakete anzeigen lassen und anschliessend löschen

esxcli software vib list | grep Bro ---> Ausgabe der entsprechenden VIB's

esxcli software vib remove -n <NAME>

Vorgehensweise bei Custom-Images der HErsteller z.B. Fujitsu / Dell etc.:

Wie zuvor auch, muss der ESXi-Host in den Maintenance Modus geschickt und die VM's entsprechend heruntergefahren werden:

vim-cmd /hostsvc/maintenance_mode_enter
vim-cmd /hostsvc/hostsummary | grep inMaintenanceMode
 
Die Custom-Images werden entsprechend vorher in einen (lokalen) Datastore hochgeladen
 
Anschliessend entsprechendes Profil anzeigen innerhalb der Offline-Bundle-Datei:

z.B.
esxcli software sources profile list -d /vmfs/volumes/datastore1/Install/VMware-ESXi-6.7.0-13473784-Fujitsu-v470-1-offline_bundle.zip
 
Ausgabe:

Name                                           Vendor   Acceptance Level  Creation Time        Modification Time
---------------------------------------------  -------  ----------------  -------------------  -------------------
Fujitsu-VMvisor-Installer-6.7-13473784-v470-1  Fujitsu  PartnerSupported  2019-04-26T05:50:45  2019-05-08T00:45:44

Jetzt das Update durchführen mit Angebe des entsprechenden Profiles aus dem Ergebnis davor:

z.B.
esxcli software profile update -d /vmfs/volumes/datastore1/Install/VMware-ESXi-6.7.0-13473784-Fujitsu-v470-1-offline_bundle.zip -p Fujitsu-VMvisor-Installer-6.7-13473784-v470-1

Ausgabe:
Update Result
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true
   VIBs Installed: Avago_bootbank_lsi-mr3_7.707.11.00-1OEM.670.0.0.8169922, ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03, EMULEX_bootbank_emulex-esx-brcmfcoecli_12.0.1113.0-01, EMULEX_bootbank_emulex-esx-elxlpfccli_12.0.257.5-01, EMULEX_bootbank_emulex-esx-elxmgmt_12.0.257.4-01, EMULEX_bootbank_emulex-esx-elxnetcli_12.0.1115.0-03, EMU_bootbank_brcm-cim-provider_12.0.1113.0-01OEM.670.0.0.7535516, EMU_bootbank_brcmfcoe_12.0.1115.0-1OEM.670.0.0.7535516, EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.670.0.0.7535516, EMU_bootbank_elxnet_12.0.1115.0-1OEM.670.0.0.7535516, EMU_bootbank_emulex-cim-provider_12.0.257.4-01OEM.670.0.0.8169922, EMU_bootbank_lpfc_12.0.257.5-1OEM.670.0.0.8169922, Fujitsu_bootbank_fujitsu-conf_6.7.0-470.1.0, Fujitsu_bootbank_pci-fujitsu-hti_9.00.06-1OEM.600.0.0.2494585, Fujitsu_bootbank_raid0_9.00.02-01, Fujitsu_bootbank_svscimprovider_9.00-16.65, INT_bootbank_i40en_1.7.17-1OEM.670.0.0.8169922, INT_bootbank_igbn_1.4.7-1OEM.670.0.0.8169922, INT_bootbank_intel-nvme-vmd_1.4.0.1016-1OEM.670.0.0.8169922, INT_bootbank_ixgben_1.7.10-1OEM.670.0.0.8169922, LSI_bootbank_lsiprovider_500.04.V0.71-0004, LSI_bootbank_vmware-storcli-007.0709.0000.0000_007.0709.0000.0000-01, MEL_bootbank_nmlx5-core_4.17.15.16-1OEM.670.0.0.8169922, MEL_bootbank_nmlx5-rdma_4.17.15.16-1OEM.670.0.0.8169922, QLC_bootbank_qedentv_3.10.23.1-1OEM.670.0.0.8169922, QLC_bootbank_qedi_2.10.5.3-1OEM.670.0.0.8169922, QLC_bootbank_qedrntv_3.10.23.0-1OEM.670.0.0.8169922, QLogic_bootbank_qlnativefc_3.1.16.0-1OEM.670.0.0.8169922, VMW_bootbank_ata-libata-92_3.00.9.2-16vmw.670.0.0.8169922, VMW_bootbank_ata-pata-amd_0.3.10-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-atiixp_0.4.6-4vmw.670.0.0.8169922, VMW_bootbank_ata-pata-cmd64x_0.2.5-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-pdc2027x_1.0-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-serverworks_0.4.3-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-sil680_0.4.8-3vmw.670.0.0.8169922, VMW_bootbank_ata-pata-via_0.3.3-2vmw.670.0.0.8169922, VMW_bootbank_block-cciss_3.6.14-10vmw.670.0.0.8169922, VMW_bootbank_bnxtnet_20.6.101.7-21vmw.670.2.48.13006603, VMW_bootbank_bnxtroce_20.6.101.0-20vmw.670.1.28.10302608, VMW_bootbank_char-random_1.0-3vmw.670.0.0.8169922, VMW_bootbank_ehci-ehci-hcd_1.0-4vmw.670.0.0.8169922, VMW_bootbank_hid-hid_1.0-3vmw.670.0.0.8169922, VMW_bootbank_ima-qla4xxx_2.02.18-1vmw.670.0.0.8169922, VMW_bootbank_ipmi-ipmi-devintf_39.1-5vmw.670.1.28.10302608, VMW_bootbank_ipmi-ipmi-msghandler_39.1-5vmw.670.1.28.10302608, VMW_bootbank_ipmi-ipmi-si-drv_39.1-5vmw.670.1.28.10302608, VMW_bootbank_iser_1.0.0.0-1vmw.670.1.28.10302608, VMW_bootbank_lpnic_11.4.59.0-1vmw.670.0.0.8169922, VMW_bootbank_lsi-msgpt2_20.00.05.00-1vmw.670.2.48.13006603, VMW_bootbank_lsi-msgpt35_09.00.00.00-1vmw.670.2.48.13006603, VMW_bootbank_misc-cnic-register_1.78.75.v60.7-1vmw.670.0.0.8169922, VMW_bootbank_misc-drivers_6.7.0-2.48.13006603, VMW_bootbank_mtip32xx-native_3.9.8-1vmw.670.1.28.10302608, VMW_bootbank_ne1000_0.8.4-2vmw.670.2.48.13006603, VMW_bootbank_nenic_1.0.21.0-1vmw.670.1.28.10302608, VMW_bootbank_net-bnx2_2.2.4f.v60.10-2vmw.670.0.0.8169922, VMW_bootbank_net-bnx2x_1.78.80.v60.12-2vmw.670.0.0.8169922, VMW_bootbank_net-cdc-ether_1.0-3vmw.670.0.0.8169922, VMW_bootbank_net-cnic_1.78.76.v60.13-2vmw.670.0.0.8169922, VMW_bootbank_net-e1000_8.0.3.1-5vmw.670.0.0.8169922, VMW_bootbank_net-e1000e_3.2.2.1-2vmw.670.0.0.8169922, VMW_bootbank_net-enic_2.1.2.38-2vmw.670.0.0.8169922, VMW_bootbank_net-fcoe_1.0.29.9.3-7vmw.670.0.0.8169922, VMW_bootbank_net-forcedeth_0.61-2vmw.670.0.0.8169922, VMW_bootbank_net-igb_5.0.5.1.1-5vmw.670.0.0.8169922, VMW_bootbank_net-ixgbe_3.7.13.7.14iov-20vmw.670.0.0.8169922, VMW_bootbank_net-libfcoe-92_1.0.24.9.4-8vmw.670.0.0.8169922, VMW_bootbank_net-mlx4-core_1.9.7.0-1vmw.670.0.0.8169922, VMW_bootbank_net-mlx4-en_1.9.7.0-1vmw.670.0.0.8169922, VMW_bootbank_net-nx-nic_5.0.621-5vmw.670.0.0.8169922, VMW_bootbank_net-tg3_3.131d.v60.4-2vmw.670.0.0.8169922, VMW_bootbank_net-usbnet_1.0-3vmw.670.0.0.8169922, VMW_bootbank_net-vmxnet3_1.1.3.0-3vmw.670.2.48.13006603, VMW_bootbank_nfnic_4.0.0.17-0vmw.670.2.48.13006603, VMW_bootbank_nhpsa_2.0.22-3vmw.670.1.28.10302608, VMW_bootbank_nmlx4-core_3.17.13.1-1vmw.670.2.48.13006603, VMW_bootbank_nmlx4-en_3.17.13.1-1vmw.670.2.48.13006603, VMW_bootbank_nmlx4-rdma_3.17.13.1-1vmw.670.2.48.13006603, VMW_bootbank_ntg3_4.1.3.2-1vmw.670.1.28.10302608, VMW_bootbank_nvme_1.2.2.27-1vmw.670.2.48.13006603, VMW_bootbank_nvmxnet3-ens_2.0.0.21-1vmw.670.0.0.8169922, VMW_bootbank_nvmxnet3_2.0.0.29-1vmw.670.1.28.10302608, VMW_bootbank_ohci-usb-ohci_1.0-3vmw.670.0.0.8169922, VMW_bootbank_pvscsi_0.1-2vmw.670.0.0.8169922, VMW_bootbank_qcnic_1.0.2.0.4-1vmw.670.0.0.8169922, VMW_bootbank_qfle3_1.0.50.11-9vmw.670.0.0.8169922, VMW_bootbank_qfle3f_1.0.25.0.2-14vmw.670.0.0.8169922, VMW_bootbank_qfle3i_1.0.2.3.9-3vmw.670.0.0.8169922, VMW_bootbank_qflge_1.1.0.11-1vmw.670.0.0.8169922, VMW_bootbank_sata-ahci_3.0-26vmw.670.0.0.8169922, VMW_bootbank_sata-ata-piix_2.12-10vmw.670.0.0.8169922, VMW_bootbank_sata-sata-nv_3.5-4vmw.670.0.0.8169922, VMW_bootbank_sata-sata-promise_2.12-3vmw.670.0.0.8169922, VMW_bootbank_sata-sata-sil24_1.1-1vmw.670.0.0.8169922, VMW_bootbank_sata-sata-sil_2.3-4vmw.670.0.0.8169922, VMW_bootbank_sata-sata-svw_2.3-3vmw.670.0.0.8169922, VMW_bootbank_scsi-aacraid_1.1.5.1-9vmw.670.0.0.8169922, VMW_bootbank_scsi-adp94xx_1.0.8.12-6vmw.670.0.0.8169922, VMW_bootbank_scsi-aic79xx_3.1-6vmw.670.0.0.8169922, VMW_bootbank_scsi-bnx2fc_1.78.78.v60.8-1vmw.670.0.0.8169922, VMW_bootbank_scsi-bnx2i_2.78.76.v60.8-1vmw.670.0.0.8169922, VMW_bootbank_scsi-fnic_1.5.0.45-3vmw.670.0.0.8169922, VMW_bootbank_scsi-hpsa_6.0.0.84-3vmw.670.0.0.8169922, VMW_bootbank_scsi-ips_7.12.05-4vmw.670.0.0.8169922, VMW_bootbank_scsi-iscsi-linux-92_1.0.0.2-3vmw.670.0.0.8169922, VMW_bootbank_scsi-libfc-92_1.0.40.9.3-5vmw.670.0.0.8169922, VMW_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.670.0.0.8169922, VMW_bootbank_scsi-megaraid-sas_6.603.55.00-2vmw.670.0.0.8169922, VMW_bootbank_scsi-megaraid2_2.00.4-9vmw.670.0.0.8169922, VMW_bootbank_scsi-mpt2sas_19.00.00.00-2vmw.670.0.0.8169922, VMW_bootbank_scsi-mptsas_4.23.01.00-10vmw.670.0.0.8169922, VMW_bootbank_scsi-mptspi_4.23.01.00-10vmw.670.0.0.8169922, VMW_bootbank_scsi-qla4xxx_5.01.03.2-7vmw.670.0.0.8169922, VMW_bootbank_sfvmk_1.0.0.1003-6vmw.670.2.48.13006603, VMW_bootbank_shim-iscsi-linux-9-2-1-0_6.7.0-0.0.8169922, VMW_bootbank_shim-iscsi-linux-9-2-2-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libata-9-2-1-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libata-9-2-2-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libfc-9-2-1-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libfc-9-2-2-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libfcoe-9-2-1-0_6.7.0-0.0.8169922, VMW_bootbank_shim-libfcoe-9-2-2-0_6.7.0-0.0.8169922, VMW_bootbank_shim-vmklinux-9-2-1-0_6.7.0-0.0.8169922, VMW_bootbank_shim-vmklinux-9-2-2-0_6.7.0-0.0.8169922, VMW_bootbank_shim-vmklinux-9-2-3-0_6.7.0-0.0.8169922, VMW_bootbank_smartpqi_1.0.1.553-12vmw.670.1.28.10302608, VMW_bootbank_uhci-usb-uhci_1.0-3vmw.670.0.0.8169922, VMW_bootbank_usb-storage-usb-storage_1.0-3vmw.670.0.0.8169922, VMW_bootbank_usbcore-usb_1.0-3vmw.670.0.0.8169922, VMW_bootbank_vmkata_0.1-1vmw.670.0.0.8169922, VMW_bootbank_vmkfcoe_1.0.0.1-1vmw.670.1.28.10302608, VMW_bootbank_vmkplexer-vmkplexer_6.7.0-0.0.8169922, VMW_bootbank_vmkusb_0.1-1vmw.670.2.48.13006603, VMW_bootbank_vmw-ahci_1.2.3-1vmw.670.1.28.10302608, VMW_bootbank_xhci-xhci_1.0-3vmw.670.0.0.8169922, VMware_bootbank_cpu-microcode_6.7.0-1.28.10302608, VMware_bootbank_esx-base_6.7.0-2.52.13473784, VMware_bootbank_esx-dvfilter-generic-fastpath_6.7.0-0.0.8169922, VMware_bootbank_esx-ui_1.33.3-12923304, VMware_bootbank_esx-update_6.7.0-2.52.13473784, VMware_bootbank_esx-xserver_6.7.0-0.0.8169922, VMware_bootbank_lsu-hp-hpsa-plugin_2.0.0-16vmw.670.1.28.10302608, VMware_bootbank_lsu-intel-vmd-plugin_1.0.0-2vmw.670.1.28.10302608, VMware_bootbank_lsu-lsi-drivers-plugin_1.0.0-1vmw.670.2.48.13006603, VMware_bootbank_lsu-lsi-lsi-mr3-plugin_1.0.0-13vmw.670.1.28.10302608, VMware_bootbank_lsu-lsi-lsi-msgpt3-plugin_1.0.0-9vmw.670.2.48.13006603, VMware_bootbank_lsu-lsi-megaraid-sas-plugin_1.0.0-9vmw.670.0.0.8169922, VMware_bootbank_lsu-lsi-mpt2sas-plugin_2.0.0-7vmw.670.0.0.8169922, VMware_bootbank_lsu-smartpqi-plugin_1.0.0-3vmw.670.1.28.10302608, VMware_bootbank_native-misc-drivers_6.7.0-2.48.13006603, VMware_bootbank_rste_2.0.2.0088-7vmw.670.0.0.8169922, VMware_bootbank_vmware-esx-esxcli-nvme-plugin_1.2.0.36-2.48.13006603, VMware_bootbank_vsan_6.7.0-2.52.13110883, VMware_bootbank_vsanhealth_6.7.0-2.52.13110884, VMware_locker_tools-light_10.3.5.10430147-12986307
   VIBs Removed: Avago_bootbank_lsi-mr3_7.703.15.00-1OEM.650.0.0.4598673, ELX_bootbank_elx-esx-libelxima.so_11.2.1197.17-03, EMULEX_bootbank_emulex-esx-brcmfcoecli_11.2.1153.13-01, EMULEX_bootbank_emulex-esx-elxlpfccli_11.2.156.20-01, EMULEX_bootbank_emulex-esx-elxnetcli_11.2.1149.0-01, EMU_bootbank_brcm-cim-provider_11.2.1153.20-01OEM.650.0.0.4240417, EMU_bootbank_brcmfcoe_11.2.1153.13-1OEM.650.0.0.4240417, EMU_bootbank_elxiscsi_11.2.1197.17-1OEM.650.0.0.4598673, EMU_bootbank_elxnet_11.2.1149.0-1OEM.650.0.0.4240417, EMU_bootbank_emulex-cim-provider_11.2.156.19-01OEM.650.0.0.4240417, EMU_bootbank_lpfc_11.2.266.0-1OEM.650.0.0.4598673, Fujitsu_bootbank_fujitsu-conf_6.5.0-421.1.0, Fujitsu_bootbank_pci-fujitsu-hti_8.20.04-1OEM.600.0.0.2494585, Fujitsu_bootbank_raid0_8.50.08-01, Fujitsu_bootbank_svscimprovider_8.50-12.65, INT_bootbank_i40en_1.7.11-1OEM.650.0.0.4598673, INT_bootbank_igbn_1.4.1-1OEM.600.0.0.2768847, INT_bootbank_intel-nvme-vmd_1.4.0.1016-1OEM.650.0.0.4598673, INT_bootbank_ixgben_1.6.5-1OEM.600.0.0.2768847, LSI_bootbank_lsiprovider_500.04.V0.65-0003, LSI_bootbank_vmware-storcli-007.0608.0000.0000_007.0608.0000.0000-01, MEL_bootbank_nmlx5-core_4.16.13.5-1OEM.650.0.0.4598673, MEL_bootbank_nmlx5-rdma_4.16.13.5-1OEM.650.0.0.4598673, QLC_bootbank_qedentv_3.9.17.1-1OEM.650.0.0.4598673, QLogic_bootbank_qlnativefc_2.1.73.0-1OEM.600.0.0.2768847, VMW_bootbank_ata-libata-92_3.00.9.2-16vmw.650.0.0.4564106, VMW_bootbank_ata-pata-amd_0.3.10-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-atiixp_0.4.6-4vmw.650.0.0.4564106, VMW_bootbank_ata-pata-cmd64x_0.2.5-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-pdc2027x_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-serverworks_0.4.3-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-sil680_0.4.8-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-via_0.3.3-2vmw.650.0.0.4564106, VMW_bootbank_block-cciss_3.6.14-10vmw.650.0.0.4564106, VMW_bootbank_bnxtnet_20.6.101.7-11vmw.650.2.50.8294253, VMW_bootbank_char-random_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ehci-ehci-hcd_1.0-4vmw.650.0.14.5146846, VMW_bootbank_hid-hid_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ima-qla4xxx_2.02.18-1vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-devintf_39.1-5vmw.650.2.50.8294253, VMW_bootbank_ipmi-ipmi-msghandler_39.1-5vmw.650.2.50.8294253, VMW_bootbank_ipmi-ipmi-si-drv_39.1-4vmw.650.0.0.4564106, VMW_bootbank_lsi-msgpt2_20.00.01.00-4vmw.650.2.50.8294253, VMW_bootbank_lsi-msgpt35_03.00.01.00-9vmw.650.2.50.8294253, VMW_bootbank_misc-cnic-register_1.78.75.v60.7-1vmw.650.0.0.4564106, VMW_bootbank_misc-drivers_6.5.0-2.50.8294253, VMW_bootbank_mtip32xx-native_3.9.5-1vmw.650.0.0.4564106, VMW_bootbank_ne1000_0.8.3-7vmw.650.2.50.8294253, VMW_bootbank_nenic_1.0.0.2-1vmw.650.0.0.4564106, VMW_bootbank_net-bnx2_2.2.4f.v60.10-2vmw.650.0.0.4564106, VMW_bootbank_net-bnx2x_1.78.80.v60.12-1vmw.650.0.0.4564106, VMW_bootbank_net-cdc-ether_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-cnic_1.78.76.v60.13-2vmw.650.0.0.4564106, VMW_bootbank_net-e1000_8.0.3.1-5vmw.650.0.0.4564106, VMW_bootbank_net-e1000e_3.2.2.1-2vmw.650.0.0.4564106, VMW_bootbank_net-enic_2.1.2.38-2vmw.650.0.0.4564106, VMW_bootbank_net-fcoe_1.0.29.9.3-7vmw.650.0.0.4564106, VMW_bootbank_net-forcedeth_0.61-2vmw.650.0.0.4564106, VMW_bootbank_net-igb_5.0.5.1.1-5vmw.650.0.0.4564106, VMW_bootbank_net-libfcoe-92_1.0.24.9.4-8vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-core_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-en_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-nx-nic_5.0.621-5vmw.650.0.0.4564106, VMW_bootbank_net-tg3_3.131d.v60.4-2vmw.650.0.0.4564106, VMW_bootbank_net-usbnet_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-vmxnet3_1.1.3.0-3vmw.650.0.0.4564106, VMW_bootbank_nhpsa_2.0.22-3vmw.650.2.50.8294253, VMW_bootbank_nmlx4-core_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-en_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-rdma_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_ntg3_4.1.3.0-1vmw.650.1.36.7388607, VMW_bootbank_nvme_1.2.1.34-1vmw.650.2.50.8294253, VMW_bootbank_nvmxnet3_2.0.0.23-1vmw.650.1.36.7388607, VMW_bootbank_ohci-usb-ohci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_pvscsi_0.1-1vmw.650.1.26.5969303, VMW_bootbank_qfle3_1.0.2.7-1vmw.650.0.0.4564106, VMW_bootbank_qflge_1.1.0.3-1vmw.650.0.0.4564106, VMW_bootbank_sata-ahci_3.0-26vmw.650.1.26.5969303, VMW_bootbank_sata-ata-piix_2.12-10vmw.650.0.0.4564106, VMW_bootbank_sata-sata-nv_3.5-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-promise_2.12-3vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil24_1.1-1vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil_2.3-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-svw_2.3-3vmw.650.0.0.4564106, VMW_bootbank_scsi-aacraid_1.1.5.1-9vmw.650.0.0.4564106, VMW_bootbank_scsi-adp94xx_1.0.8.12-6vmw.650.0.0.4564106, VMW_bootbank_scsi-aic79xx_3.1-5vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2fc_1.78.78.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2i_2.78.76.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_scsi-fnic_1.5.0.45-3vmw.650.0.0.4564106, VMW_bootbank_scsi-hpsa_6.0.0.84-1vmw.650.0.0.4564106, VMW_bootbank_scsi-ips_7.12.05-4vmw.650.0.0.4564106, VMW_bootbank_scsi-iscsi-linux-92_1.0.0.2-3vmw.650.0.0.4564106, VMW_bootbank_scsi-libfc-92_1.0.40.9.3-5vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-sas_6.603.55.00-2vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid2_2.00.4-9vmw.650.0.0.4564106, VMW_bootbank_scsi-mpt2sas_19.00.00.00-1vmw.650.0.0.4564106, VMW_bootbank_scsi-mptsas_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-mptspi_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-qla4xxx_5.01.03.2-7vmw.650.0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-3-0_6.5.0-0.0.4564106, VMW_bootbank_smartpqi_1.0.1.553-10vmw.650.2.50.8294253, VMW_bootbank_uhci-usb-uhci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usb-storage-usb-storage_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usbcore-usb_1.0-3vmw.650.2.50.8294253, VMW_bootbank_vmkata_0.1-1vmw.650.1.36.7388607, VMW_bootbank_vmkplexer-vmkplexer_6.5.0-0.0.4564106, VMW_bootbank_vmkusb_0.1-1vmw.650.2.50.8294253, VMW_bootbank_vmw-ahci_1.1.1-1vmw.650.2.50.8294253, VMW_bootbank_xhci-xhci_1.0-3vmw.650.0.0.4564106, VMware_bootbank_cpu-microcode_6.5.0-2.57.9298722, VMware_bootbank_esx-base_6.5.0-2.61.10175896, VMware_bootbank_esx-dvfilter-generic-fastpath_6.5.0-1.36.7388607, VMware_bootbank_esx-tboot_6.5.0-2.61.10175896, VMware_bootbank_esx-ui_1.27.2-9210160, VMware_bootbank_esx-xserver_6.5.0-2.50.8294253, VMware_bootbank_lsu-hp-hpsa-plugin_2.0.0-6vmw.650.2.50.8294253, VMware_bootbank_lsu-lsi-lsi-mr3-plugin_1.0.0-10vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-lsi-msgpt3-plugin_1.0.0-7vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-megaraid-sas-plugin_1.0.0-8vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-mpt2sas-plugin_2.0.0-6vmw.650.1.26.5969303, VMware_bootbank_native-misc-drivers_6.5.0-0.0.4564106, VMware_bootbank_net-ixgbe_3.7.13.7.14iov-12vmw.550.2.62.2718055, VMware_bootbank_rste_2.0.2.0088-4vmw.650.0.0.4564106, VMware_bootbank_vmware-esx-esxcli-nvme-plugin_1.2.0.32-2.50.8294253, VMware_bootbank_vsan_6.5.0-2.61.10175901, VMware_bootbank_vsanhealth_6.5.0-2.61.10107908, VMware_locker_tools-light_6.5.0-1.47.8285314
   VIBs Skipped: Avago_bootbank_lsi-msgpt3_17.00.00.00-1OEM.650.0.0.4598673, QLogic_bootbank_qlogic-adapter-provider_1.6.96-1045108

--> Neustart des Hosts

© 2024 ziggymania.de Designed S.Wommer
Wir benutzen Cookies

Wir nutzen Cookies auf unserer Website. Einige von ihnen sind essenziell für den Betrieb der Seite, während andere uns helfen, diese Website und die Nutzererfahrung zu verbessern (Tracking Cookies). Sie können selbst entscheiden, ob Sie die Cookies zulassen möchten. Bitte beachten Sie, dass bei einer Ablehnung womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen.